Siemens LUT420, Wall Mount, Local HMI, 100-230VAC, CSA General Purpose
Price
$1,762.00
CAD
Stock
25+ In Stock
Specifications
Brand
Measuring Range
- 0.3 … 60 m (1 … 196 ft), transducer dependent
Input Discrete
- 0 ... 50 Vdc switching level
- Logical 0 < 10 Vdc
- Logical 1 = 10 ... 50 Vdc
- Maximum 3 mA
Output Transducer Frequency
- 10 ... 52 kHz
Output Ultrasonic Transducer
- Compatible transducers: All EchoMax. and ST-H series transducers
Output Relays
- 1 SPDT Form C, NO or NC relay, rated 1A at 250 Vac, non-inductive and 3A at 30 Vdc
- 2 SPST Form A, NO relays, rated 5A at 250 Vac, non-inductive and 3 A at 30 Vdc
Output mA Output
- 4 … 20 mA, isolated
Output Maximum Load
- 600 Max. in ACTIVE mode
- 750 Max. in PASSIVE mode
Output Resolution
- 0.1 % of Range
Error in Measurement Accuracy
- Standard operation: ± 1 mm (0.04 inch) plus 0.17 % of measured distance
- High accuracy OCM: ± 1 mm (0.04 inch), within 3 m (9.84 ft) range
Resolution Accuracy
- Standard Operation: 0.1 % of Range or 2 mm (0.08 inch), whichever is greater
- High accuracy OCM: 0.6 mm (0.02 inch), within 3 m (9.84 ft) range
Temperature Compensation Accuracy
- -40° to +150° C (-40° to +300° F)
- Integral temperature sensor in transducer
- External TS-3 temperature sensor (optional)
- Programmable fixed temperature values
Installation Conditions
- Location - Indoor/outdoor
- Installation category - II
- Pollution Degree - 4
Ambient Conditions
- Ambient temperature (Enclosure) - -20 … +50° C (-4 … +122° F)
- Storage temperature - -20 … +50° C (-4 … +122° F)
Weight
- Enclosure with display lid - 1.3 kg (2.87 lb)
- Enclosure with blank lid - 1.2 kg (2.65 lb)
Material (Enclosure)
- Polycarbonate
Degree of Protection
- Enclosure with display or blank lid - IP65/Type 4X/NEMA 4X
- Enclosure with blank lid and knockout removed - IP20
Remote Display Lid
- IP65/Type 3/NEMA 3
Cable Transducer and mA Output Signal
- Transducer, mA output: 2 copper conductors, twisted, with foil shield/drain wire, 300 V 0.5 … 0.75 mm² (22 … 18 AWG)
- Relay/power to be copper conductors per local requirements to meet 250 V 5 A contact rating
Cable Maximum Separation Between Transducer and Transceiver
- 365 m (1 200 ft)
Displays and Controls
- 60 x 40 mm (2.36 x 1.57 inch) removable LCD, 240 x 160 pixels resolution
- Operational up to 5 m from enclosure base
Programming: Primary
- 4 Local push buttons
Programming: Secondary
- PC running SIMATIC PDM
- PC running Emerson AMS Device Manager
- PC running a web browser
- PC Rrunning a Field Device Tool (FDT)
- Field Communicator 375/475 (FC375/FC475) Memory
- 512 kB flash EPROM
- 1.5 MB flash for data logging
Power Supply
- AC Version: 100 ... 230 Vac ± 15 %, 50/60 Hz, 36 VA Fuse: 5 x 20 mm, Slow Blow, 0.25 A, 250 V
Power Supply
- DC Version: 10 … 32 Vdc, 10 W Fuse: 5 x 20 mm, Slow Blow, 1.6 A, 125 V
Certificates & Approvals: General
- CCSAUS
- CE
- UKCA
- FM
- UL Listed
- RCM
- EAC
- KC
- MCERTS
Certificates & Approvals: Hazardous
- Non-incendive (Canada) -CSA Class I, Div. 2, Groups A, B, C, D, Class II, Div. 2, Groups F, G, Class III
- Shipping - Lloyd's Register, ABS
Communication
- HART 7.0, USB