Measuring Range in Liquids
- 0.25 ... 5 m (0.8 ... 16.4 ft)
Measuring Range in Bulk Solids
- 0.25 ... 3 m (0.8 ... 9.8 ft)
AC Version (Relay)
- 2 SPDT Form C contacts, rated 5 A at 250 Vac or 30 Vdc, resistive load
- rated 1 A at 48 Vdc resistive load
DC Version (Relay)
- 2 SPDT Form C contacts, rated 5 A at 30 Vdc, resistive load
- rated 1 A at 48 Vdc resistive load
DC Version (Transistor)
- 2 switches, rated Max. 100 mA, 48 Vdc
Repeatability Accuracy
- 0.25 % of Measuring Range
Ambient Temperature
- -40° to +60° C (-40° to +140° F)
Storage Temperature
- -40° to +60° C (-40° to +140° F)
If Mounted in Metal Threads
- -20° to +60° C (-5° to +140° F)
Material
- Polycarbonate with gasket
Threaded Mounting
- 2” NPT [(Taper), ASME B1.20.1]
- R 2” [(BSPT), EN 10226]
- G 2” [(BSPP), EN ISO 228-1]
Optional Flange Adapter
- For 3” ASME , DN 65, PN 10, and JIS 10 K3B
Sanitary Mounting
- 4” Sanitary Fitting Clamp
AC Version
- 100 ... 230 Vac, ± 15 %, 50/60 Hz, Max. 12 VA, 5 W
Display
- LCD, three digits, 9 mm (0.35 inch) high, for display of distance between sensor face and material, multi-segment graphic for operating state
Electronics/Enclosure
- Connection: terminal block, Max. 2.5 mm² (14 AWG) solid/1.5 mm² (16 AWG) stranded
Cable Inlet
- 2 x 1/2” NPT or 2 x PG 13.5